Sikalastic®-611 R AP
HIGH PERFORMANCE ONE-COMPONENT LIQUID APPLIED POLYURETHANE ROOF WATERPROOFING MEMBRANE
Sikalastic®-611 R AP is a one-component, cold applied, moisture-triggered polyurethane waterproofing membrane. It cures to form a seamless, durable and chemical resistant, waterproofing solution for flat roofs and external balconies with primer and topcoat.
- 1-part, ready to use
- Highly durable system
- Moisture triggered chemistry (MTC)
- Fast curing and rain resistant
- High solids content
- Self-leveling properties
- Cold applied - requires no heat or flame
- Applied by squeegee, brush, or roller
- Metal tin container can be fully recycled
- Excellent crack-bridging ability
Usage
Sikalastic®-611 R AP may only be used by experienced professionals. The Product is used for:- Flat and sloping fully exposed roof structures
- New construction and refurbishment projects
- Waterproofing and renovation of old roofs to extend service life
- Roofs with numerous details such as penetrations, drains, roof lights and complex geometry
- Concrete and cementitious substrates
- Metal
- Bituminous sheet membranes
- Bituminous coatings
- Brick
- Unglazed ceramic tiles
Advantages
- 1-part, ready to use
- Highly durable system
- Moisture triggered chemistry (MTC)
- Fast curing and rain resistant
- High solids content
- Self-leveling properties
- Cold applied - requires no heat or flame
- Applied by squeegee, brush, or roller
- Metal tin container can be fully recycled
- Excellent crack-bridging ability
Packaging
18 kg container
Colour
Grey
Product Details
APPROVALS / STANDARDS
- Crack bridging (BS EN 14891:2017), Tensile Strength & Elongation at break (ASTM D 412-16), Tear Strength (ASTM D 624-00), Shore A hardness (ASTM D2240-15), Weight loss (ASTM C 836-15) tested by QUATEST 3®, Vietnam. Test report: KT3-01826BXD1
- Tensile performance, Tear performance, Heating elongation and shrinkage state, Tensile performance after deterioration treatment, Deterioration state of elongation, Solid content, Density of cured product according to CNS 8644:2014 tested by TGS Taipei Laboratory. Test Report: PL-21-00900XA
Chemical base
One-component, moisture-triggered aromatic polyurethane
Shelf life
9 months from date of production if stored properly in original, unopened and undamaged sealed container. Refer to expiry date on the container.
Storage conditions
Product must be stored properly in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +5 °C and +30 °C. Higher storage temperatures may reduce shelf life of product. Prevent exposure to sunlight, frost and heat.
Density
1.40 ± 0.05 kg/L at +23° C | (EN ISO 2811-1) |
Solid content by weight
92% ±3%, (23°C, 50% r.h.)
System Structure
Note: For detailed reinforcement information refer to the Sika Method Statement: Sikalastic®-611 R AP
Note: These figures are theoretical and do not include for any additional material required due to surface porosity, surface profile, variations in
level and wastage etc.
Roof Coating:
Layer | Product | Consumption |
Primer | please refer to substrate pre-treatment | please refer to PDS of the Primer |
1st Base coat | Sikalastic®-611 R AP | 1.0 ~ 1.4 kg/m2 |
2nd Base Coat | Sikalastic®-611 R AP | 0.75 ~ 1.0 kg/m2 |
Topcoat | Sikalastic® U-Coating or Sikalastic® ExcelTop | ≥ 0.3 kg/m2/layer |
Roof Waterproofing System:
System | 1st base coat | 2nd base coat |
SikaRoof® MTC-05 UV SikaRoof® MTC-05 UV AP | ≥ 1.0 kg/m2 | ≥ 0.75 kg/m2 |
SikaRoof® MTC-08 UV AP | ≥ 1.0 kg/m2 | ≥ 1.0 kg/m2 |
SikaRoof® MTC-10 UV AP | ≥ 1.4 kg/m2 | ≥ 1.0 kg/m2 |
Shore A Hardness
~40 | ASTM D 2240-15 |
Tensile Strength
~3.0 N/mm2 | ASTM D412-16 |
Crack Bridging Ability
No crack at 5 mm crack width(Unreinforced) | BS EN 14891 : 2017 |
Tensile Adhesion Strength
≥ 1.0 N/mm2 | ASTM D7234-21 |
Tear Strength
~10 kN/m | ASTM D624-00 |
Service temperature
-20 °C to +80 °C max
CHEMICAL RESISTANCE
Sikalastic®-611 R AP resists contact with weak acids and alkalis regulated by JIS A 6021.
Application
Product Temperature
+5 °C min / +40 °C max
Ambient Air Temperature
+5 °C min / +40 °C max
Relative Air Humidity
5% min / 80% max Relative Humidity
Dew Point
Beware of condensation. The substrate and uncured applied membrane must be at least +3 °C above dew point to reduce the risk of condensation or blooming on the membrane finish.
Substrate Temperature
+5 °C min / +40 °C max
Substrate Moisture Content
Refer to Product Data Sheet of the appropriate primer
Pot Life
Product will cure rapidly in high temperatures combined with high air humidity. Skin formation starts after ~2 hour (+20 °C / 50 % r.h.).
Applied Product Ready for Use
Ambient conditions | Touch dry | Full cure |
+23°C/50% r.h. | 3 hours | 16 hours |
+30°C/50% r.h. | 2 hours | 12 hours |
Be aware that impact of heavy or rain showers can physically damage the still liquid membrane.
Note: Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity
EQUIPMENT
Select the most appropriate equipment required for the project:
SUBSTRATE PREPARATION EQUIPMENT
- Abrasive blast cleaning / planing / scarifying or grinding equipment.
- Manual or mechanical wire brushes.
- High pressure power washer.
For other types of preparation equipment, contact Sika Technical Services.
MIXING EQUIPMENT
- Electric single or double paddle mixer (300–400 rpm) with spiral paddle
APPLICATION EQUIPMENT
- Brush: Soft bristle
- Roller: Solvent resistant fleece
- Float trowels
SUBSTRATE PREPARATION
Substrate | Primer |
Cementitious including concrete slabs | Sikalastic® U-Primer / US Urethane Primer / Sikafloor®-161 |
Brick and Stone | Sikalastic® U-Primer / US Urethane Primer / Sikafloor®-161 |
Ceramic Tiles (unglazed) | Sikalastic® U-Primer / US Urethane Primer / Sikafloor®-161 |
Bituminous coatings (aged) / Bituminous felts (aged) | Sikalastic® Metal Primer / PW-F Primer |
Metals* | Sikalastic® Metal Primer / PW-F Primer |
Existing SikaRoof MTC System | Sikalastic® Reactivation Primer / Interlayer Primer J |
*Ferrous, stainless steel, aluminium, lead, zinc; Factory coated metal sheeting must be tested for adhesion before proceeding
NOTE:
For thecomsumption rates and waiting time / overcoating please refer to the PDS of the appropriate cleaner and primer. Other substrates most be testedfor their compatibility. If in doubt, applly a test area first.
MIXING
IMPORTANT
Avoid over-mixing to minimise air entrainment.
Product is supplied ready to use. Before application, mix for at least 1 minute or until the liquid is uniform.
APPLICATION
IMPORTANT
Protect from rain
After application, the product must be protected from heavy rain or rain showers until dry to prevent surface damage.
IMPORTANT
Application of successive coats
To prevent a reduction in product performance the following actions are necessary when applying successive coats.
- Ensure product is totally dry and the surface is without pinholes before applying successive coats.
- Remove surface water between coating applications.
- Confirm overcoating times have been achieved between coating applications.
IMPORTANT
No application on rising moisture
Do not apply on substrates with rising moisture.
INSTALLATION PROCEDURE
Reference must be made to further documentation where applicable, such as a relevant method statement, application manual and installation or working instructions.
PRIMER
Equipment:
- Fleece roller
- Brush
- Pour the mixed Product onto the surface. The consumption is specified in the individual primer Product Data Sheet Application Information.
- Apply the Product evenly over the surface with a brush or fleece roller.
- Back roll the surface in two directions at right angles with a fleece roller.
The coating is continuous and pore free.
ROOF WATERPROOFING
Reinforced waterproof membrane
Equipment:
- Fleece roller
- Brush
- Float trowels
1st coat
- Install the detailing first (such as corners, upstands, joints) before installation of the main horizontal surfaces.
- Pour the mixed Product onto the substrate. The consumption is specified in Application Information.
- Apply the Product with either a trowel, brush or a fleece roller.
- IMPORTANT Avoid going back to re-work areas that are partially dried as this may damage the surface finish. Back roll the surface in two directions at right angles with a fleece roller.
The coating is continuous and pore free.
Reinforcement application
- For the best results work 1.0 m at a time lengthways applying the 1st coat and embedding the reinforcement.
- Make sure reinforcement overlaps are greater than 50 mm.
- Lay the reinforcement onto the wet 1st coat
- Use a short pile roller to roll over the reinforcement and resin
The coating is continuous and pore free.
2nd coat
- Check if the reinforcement is embeded properly, if necessary use sand paper to unsure that the surface is even. If the surface was contaminated with dust or dirt clean the surface with water and light detergent, wait until the surface is dry before applying 2nd coat. Remove any standing water before application.
- Install the detailing first (such as corners, upstands, joints) before installation of the main horizontal surfaces.
- Pour the mixed Product onto the substrate. The consumption is specified in Application Information.
- Apply the Product with one either a brush or a fleece roller.
- IMPORTANT Avoid going back to re-work areas that are partially dried as this may damage the surface finish. Back roll the surface in two directions at right angles with a fleece roller.
The coating is continuous and pore free.
Top coat
- Install the detailing first (such as corners, upstands, joints) before installation of the main horizontal surfaces.
- Mix 2-part top coat according to Product Data Sheet.
- Pour the mixed Product onto the substrate. The consumption is specified in the individual primer Product Data Sheet Application Information.
- Apply the Product with either a brush or a fleece roller.
- IMPORTANT Avoid going back to re-work areas that are partially dried as this may damage the surface finish. Back roll the surface in two directions at right angles with a fleece roller.
The coating is continuous and pore free.
CLEANING OF TOOLS
Clean all tools and application equipment with thinner immediately after use. Hardened material can only be removed mechanically.